Modell nr: SPS40VDC24000W-2-19
Märke: Apm
Härstamning: Kina
Input Voltage: 190~265VAC
Input Frequency: 47~63Hz
Input Power Max: 28.5KW
Power Factor: ≥0.98
Output Voltage Range: 0~40V
Output Current Range: 0~720A
Output Power Range: 0~24000W
Height: 19U
Warranty: 2 years
Förpackning: kartonger
Produktivitet: other
Transportfordon: Air
Hemorten: KINA
Stödja: other
Certifikat: CE
HS-nummer: 8504401990
Hamn: DHL
Betalning Typ: T/T
Incoterm: EXW
APM SYS -serie Programmerbart DC -kraftförsörjningssystem som fungerar utmärkt under verkliga förhållanden ger goda kraftlösningar till kunderna. Det kan enkelt parallellt upp till 6 enheter som kan 24 kW 720A med aktuell delning för bulkkraftsapplikationer. Seriesanslutning kan leverera spänningsområde upp till 240V.Det täcker denna 12V 15 amp strömförsörjning och 6 volt DC strömförsörjning för att uppfylla kundens krav. Denna serie är tillämplig på flera sektorer som elektriska, belysnings- och luftfartssektorer och den kan också tillämpas på Enterprises produktionstest .
Förutom 40V DC -källsystemet kan det också ha högre spänningsopition för 150V DC -källsystem, 200V DC -källsystem, vänligen kontrollera mer med den regionala försäljningen.
Ansökningsområde :
Denna serie är tillämplig på flera sektorer som elektriska, belysnings- och luftfartssektorer och den kan också tillämpas på Enterprises produktionstest.
Produktfunktioner:
● Med exakt spänning och strömmätningsförmåga.
● Kodad knopp, multifunktionstangentbord.
● Standard RS232/RS485/USB -kommunikationsgränssnitt, LAN och GPIB är valfritt.
● Fjärravkänningslinjespänningskompensation.
● Utrustar med List Waveform -redigeringsfunktion.
● Använd standardkommandona för programmerbar instrumentering (SCPI) kommunikationsprotokoll.
● Har erhållit CE -certifiering.
Teknisk specifikation:
ltem | MODEL | SYS40VDC24000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 150A | |
5 | Input Power Max | 28.5kW | |
6 |
Power Factor at 220VAC Input ,Full Load |
0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~40V | |
9 | Output Current | 0~720A | |
10 | Output Power | 24kW Max | |
11 | Load Regulation | Voltage | 240mV |
12 | Current | 0.75A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~40V |
16 | Resolution | 0.1mV | |
17 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
18 | Current Setting | Range | 0~720A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 80mVp-p/12mVrms |
22 | Current | 450mA(Full Range),60mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~40V |
24 | Resolution | 0.1mV | |
25 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc |
|
26 | Current Setting | Range | 0~720A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~240V | |
30 | Output Current | 0~120A | |
31 | Output Power | 24kW Max | |
32 | Load Regulation | Voltage | 240mV |
33 | Current | 0.75A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~240V |
37 | Resolution | 10mV | |
38 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
39 | Current Setting | Range | 0~120A |
40 | Resolution | 1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 120mVp-p/18mVrms |
43 | Current | 300mA(Full Range),40mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~240V |
45 | Resolution | 10mV | |
46 | Accuracy |
0.1%+0.1%F.S. at 0< Ouput
Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc |
|
47 | Current Setting | Range | 0~120A |
48 | Resolution | 1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232(Standard); LAN,GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*1064.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*1240.0*820.0 mm | |
67 | Unit Net Weight | 100.0kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 160.0kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
*FS representerar det maximala värdet för utgångsområdet.
* N står för antalet installerade strömförsörjningsenheter och N är större än 1.